A pump that leaks is rarely a pump problem. It is usually a neck finish that was never checked against the closure before the bottle was made.

What a neck finish is

The neck finish is the top of the bottle: the thread, the bead under it and the opening. It is described by three numbers — thread diameter, thread pitch and the height of the finish. A 24/410 is not the same as a 24/415, and neither is interchangeable with a 28/410.

Why it goes wrong

  1. The closure was bought separately. A pump sourced from a different supplier is matched by eye, not by drawing.
  2. The mould was copied from a sample. A sample bottle measured with calipers gives a number, not a tolerance.
  3. Two suppliers, one assumption. The filler assumes the bottle supplier checked; the bottle supplier assumes the filler specified.

How to avoid it

Send the closure first. Not a photo of it — the physical pump, or the drawing with the thread spec and the torque. We check the neck against the closure before the bottle is quoted, because a mismatched neck is discovered at the filling line, which is the most expensive place to discover anything.

If the closure has not been chosen yet, choose it before the bottle. The closure decides the neck, and the neck decides the bottle.

The three questions to ask any supplier

  1. Which neck finish is this mould cut for?
  2. What is the tolerance on the thread?
  3. Can you send the drawing before the sample?

A supplier who cannot answer the first question in one line has not checked.